Automatic Isoperibol Calorimeter for Determine the Calorific

Application: TS-AI4000 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material. Analysis time is about 15~25 min; Conform...

Standard: ASTM -- D5865 model: TS-AI4000 E-mail: robin@pro-trueview.com

Application:

TS-AI4000 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material.
Analysis time is about 15~25 min;
Conform to ISO and ASTM international standard

Highlights:
①Vertical type calorimeter, large water quantity. Difference of jacket water temperature in each test is less than 0.1K.
②Automatic water temperature adjustment (at final stage, bucket temperature is 1K higher than jacket temperature), water amount determination and test.
③Support oxygen bomb air tightness examination, no complicated elevating mechanism and compressor in calorimeter.
④SDACM4000 calorimeter has expert diagnostic, self-protection, self-diagnostic function.
⑤Authentic test data and calorific value, no software modification.
⑥Strong data processing capability, statistics report and printing function; Capable of connecting with network and balance by RS232 interface.

Specification:

Description

TS-AI4000

Analysis Time

15min-25min

Temperature Resolution

0.0001K

Precision(RSD)

≤0.15%

Heat Capacity Stability

≤0.25% within three months

System Structure

Vertical

Conformance with Standard

ASTM D5865, ISO1928  GB/T213-2008               

Test per Hour

2~4

Bomb volume

282ml

Calorimeter Type

Isoperibol

Oxygen Filling

Semi-automatic

Bomb Washing

Manual

Max.Bomb pressure

20Mp

Bomb Identity

No

Gas Requirement

99.5% Oxygen

Water Requirement

Distilled  Water

Energy Measurement Range

0~50000J

Bucket Filling

Automatic

Constant Volumetric Tank with Temp Control Device

No

Independent Bucket and Jacket Water System

No

Stirring Method

Blade

Power Inverter

No

Reproducibility based on analysis of 1g Benzoic Acid

0.15%

Average Temperature Increase

2℃

Temperature Measurement

PT1000

Working Temperatures

≦32℃

Cooling method

Automatic by water circulation

Network

Yes

Power

220V(-15% +10%)50/60Hz

Max Power

0.5kW

Dimension

Main body: 600*417*908

Weight

106kg

Advance Calculation

No

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes