Have any questions? robin@pro-trueview.com 0086-18007322239

You in this column



Dietary Fiber Analyzer

Main feature: The whole process without transferring samples, to avoid operating errors Set of enzymatic hydrolysis, stirring, heating, constant temperature, plus liquid, precipitation, pumping in one Mobile semi-circular silicon carbide he...

Standard: model: TS-DF602 E-mail: robin@pro-trueview.com

Main feature:

 The whole process without transferring samples, to avoid operating errors
 Set of enzymatic hydrolysis, stirring, heating, constant temperature, plus liquid, precipitation, pumping in one
 Mobile semi-circular silicon carbide heater, heating fast and stable, safe operation
 Special filter pump, fiber patented products, apply to all corrosive solvents
 Pneumatic function to ensure thorough digestion of the sample
 Directly control the temperature of the enzymatic hydrolysis of the liquid, the enzymatic effect to achieve the best condition
 7-inch ultra-fine color screen, touch screen control, the interface avant-garde fashion is simple and simple
 Heater detection in place

 Core Technology:

 Special filter pump:Fiber patented products, 30 years of industry experience developed a unique formula raw materials.Applicable to all corrosive solvents, the use of a wider range, fully reflects the fiber inspection technology and strength;
 Integrated anti - misoperation interface design:Completely avoid the wrong button caused by the misuse, reflecting the ultimate concept of human nature;

Special condensing tube:Integrated condensation and liquid integration, flexible and convenient operation;
 
Pneumatic function:
Without the need for agitator immersed in the sample, eliminating the sample sticking to the stirrer is difficult to clean the error caused, but also to avoid the risk of rocking stirring;

Rise and fall timing dual system:Designed for dietary fiber design tailored temperature control;Breaking the conventional only temperature control timing mode, to avoid the cooling temperature control time error;
 
Technical parameters: (★said the company's product features) 

1. 7 inch ultra-fine color screen, touch type;
2. Test range: 0 ~ 100%;
3. ★Batch time: 3 hours;
4. Analysis temperature range: room temperature ~ 200 ℃;
5. ★Temperature control mode: the cooling system control;
6. Temperature control accuracy: ± 0.5 ℃;
7. ★Mixing mode: air pressure mixing, no interference, no mutual pollution;
8. ★Results Standard deviation: ≤0.5%;
9. Recovery: ≥99%;
10 ★Environmental protection: no need for constant temperature water bath and filter bottles, no smell floating, just ordinary standard laboratory;
11. ★Anti-error performance: no sample transfer, all enzymatic hydrolysis and washing filter, directly on the instrument to complete;
12. Number of samples: 1 to 6 samples at the same time;
13. ★Heating method: mobile semi-circular silicon carbide independent heater;
14. Power:220V±10%,50~60HZ;
15. Rated power:2000W;
16. Size:700×400×600(mm);
17. Weight:38kg;