You in this column



Automatic Penetrometer(Low temperature)

Summary 1.The instrument is designed and made as per the standards GB/T4509 Standard Test Method for Penetration of Bitumen T0604 Bitumen Penetration Test in the standard JTJ052-2000 Specifications and Test Methods of Bitumen and Bituminou...

Standard: ASTM -- D5 model: SYD-2801I E-mail: robin@pro-trueview.com

Summary
1.The instrument is designed and made as per the standards GB/T4509 Standard Test Method for Penetration of
    Bitumen, T0604 Bitumen Penetration Test in the standard JTJ052-2000 Specifications and Test Methods of Bitumen
    and Bituminous Mixtures for Highway Engineering and ASTM D5.
2.The instrument is suitable to determine the penetration of highway bitumen, modified asphalt, as well as liquid
    petroleum asphalt or residue of emulsified asphalt after evaporation.
3.The penetration of bituminous materials is expressed as the distance that a 100 g±0.05 g standard needle vertically
    penetrates into the sample without measurable fraction in 5 s at a constant temperature bath of 25±0.1 ℃. It is used for
    evaluating the consistency of asphalt. The larger the penetration is; the thinner and softer the asphalt is.
4.The instrument can also be used for inspecting industry materials such as solid granule, powder, colloid, as well as
    food materials such as cream, glycine, etc. It has been widely used in the field of food industry, highway and traffic
    departments and other departments.

I.Main technical specifications
1.Measurement range: 0 penetration~600 penetrations;
2.Resolution: 0.1 penetration;
3.Timing range: 0s~60 s, and the error is less than ±0.1 s.
4.Heating power: 200 W;
5.Temperature controlling accuracy: 25±0.1 ℃ (Note: the ambient temperature should not be higher than 20 ℃);
6.Data saved: 30 groups;
7.Constant temperature bath: harden glass container
a.Bath volume:5.5L
b.Temperature range: (5.0~100.0)℃
c.Temperature accuracy: ±0.1℃
d.Total consumption:less 1800W
e.Outline dimension: 420mm×380mm×900mm(L*W*H)
f:Power supply: AC(220±10%)V,50Hz
8.Stirrer: a magnetic stirrer;
9.Standard needle: 2.5±0.05 g and it conforms to the requirements of GB/T4509 and T0604.
10.Shifting holder: It has two ways to adjust the height of standard needle, so it is convenient to let the needle tip just
      touch the sample surface.
11.Power supply: AC 220 V±10%, 50 Hz.
12.Outline dimension: 280mm×350mm×700mm(L*W*H)

ISYD-2801I Automatic Penetrometer Accessories and Documents List
No. Name Unit Qty Memo
1 SYD-2801I Automatic Penetrometer Set 1  
2 Low temperature constant temperature bath Set 1  
3 Standard needle(50㎜,2.5g±0.05g) Piece 3  
4 Weight (50g) Piece 1  
5 Asphalt sample container Φ55×H35 (small sample container) Piece 3  
Φ70×H45 (big sample container) Piece 3 Optional  
Φ55×H70(special sample container) Piece 3 Optional  
6 Mercury thermometer (0~50 ℃ scale division is 0.1 ℃) Piece 1  
7 W-line Piece 1  
8 Power line(250V6A) Piece 1  
9 Triangle holder Piece 1  
10 Fuse(3A、Ф5×20) Piece 3
Used for penetration
Instrument
 
11 Stylus printer Piece 1  
12 Regulated power supply (input 220V/50Hz output 5V/3A) Piece 1  
13 25-pin data cable Piece 1  
14 Print paper (suitable for the above stylus printer) Roll 1 Except installed in the instrument
15 Operation manual Piece 1  
16 Quality certificate Piece 1  
17 Product Warranty Card Piece 1  
18 Software CD Piece 1  
 



IISYD-2801I Automatic Penetrometer's Reagent and Auxiliary Equipments 


No. Name Specification Quantity Memo
1 Glycerol 500ml 1 bottle  
2 Bitumen solvent(Kerosene) 1L 2L/bucket Bitumen test

 
3 Talcum powder   500 g  
4 Scraper   1 piece  
5 Hairbrush 2cm width 2 pieces  
6 Electric furnace 1000W 1 piece
Bitumen test




Notes:
1The reagent and equipments for installing the instrument are supplied by end-users themselves.
2The usagemanagement and saving of poisonous and harmful reagentpls operate according to the relative principle.