Have any questions? robin@pro-trueview.com 0086-18007322239

You in this column



Gas Chromatography

Description: 1.1The temperature control accuracy can be precise to 0.01℃by the new integrated digital electronic circuit with high control precision and reliable performance. 1.2It has the functions of self-diagnosis for boot stopwatch (...

Standard: model: TS5890N E-mail: robin@pro-trueview.com

Description:
1.1 The temperature control accuracy can be precise to 0.01 ℃ by the new integrated digital electronic circuit with high control precision and reliable performance.

1.2 It has the functions of self-diagnosis for boot, stopwatch (for determining the flow), timer operation, storage protection for power off, keyboard locking, anti-interference, network data communication and remote control.

1.3 It can gets lower limit of detection by unique injector system design.

1.4 You can choose automatic/manual gas six-way valve injector, headspace injector, thermal desorption injector, cracking furnace injector, methane conversion furnace and auto-injector.

1.5 The program heating and the furnace temperature precision can be controlled stable and fast.

1.6 Optional detectors are FID, TCD, ECD, FPD, NPD and PDHID. All detectors can control the temperature individually. FID is easy to assemble and disassemble for cleaning or changing the nozzle. TCD stable time is ≤20min.
 
Auxiliary Facilities for option
DK-400A: a new generation automatic headspace injector. 
 
Application Fields
TS5890N is widely used for the analysis of oil extraction and refining, petrochemical, fine chemical, food safety, environmental protection, electronic high-purity gas industry, scientific research institutes, QC, safety supervision, public security forensic and national security and so on.

Specifications:

 Column Oven

 Furnace dimensions:  28 x 30 x 18cm
 Temperature operating range  Higher than the room temperature of 5℃-450℃
 Temperature setting  1℃;programmed heating rate 0.1℃
 Maximum heating speed  120℃/min
 Temperature stability  It will be 0.01℃, when the environment temperature changes 1℃
 Programmed temperature steps  7 steps
 Column loss can be compensated (dual channel column)

 Injectors

 Various injector available: packed column injectors, split/splitless capillary column injectors or cool on-column injectors

 Detectors

 FID

 Max temperature control  400℃
 LOD  ≤5 x 10 -12 g/s [n-C16]
 Linear dynamic range  ≥107
 Drift  ≤5 x 10 -13A/30min 
 Noise  ≤2 x 10 -13 A

 TCD

 Max using temperature  400℃
 Sensitivity  ≥10000mv.ml/mg [n-C16]
 Linear dynamic range  ≥104
 Drift  ≤ 10 0uV/30min
 Noise  ≤20uA

 FPD

 Max using temperature  250℃
 LOD  ≤2 x 10 -13 g/s(P),≤5 x 10 -11 g/s (S)
 Linear dynamic range  ≥103(P),≥102(S)
 Noise  ≤2 x 10 -12 A
 Drift  ≤4 x 10 -11A/30min

 ECD

 Max using temperature  350℃
 Drift  ≤5 0uV/30min
 LOD  ≤1 x 10 -14 g/ml(y-666)
 Linear dynamic range  ≥104
 Noise  ≤20uA

 NPD

 Max using temperature  400℃
 LOD  ≤5 x 10 -13 g/s(P),≤1 x 10 -12 g/s (N)
 Noise  ≤4 x 10 -13 A
 Drift  ≤2.5 x 10 -12A/30min
 Linear dynamic range  ≥103(P),≥103(N)

 PDHID

 LOD  ≤5ppb
 

yle="width: 1336px; height: 480px;" />