Pensky-Martens Closed-Cup Flash Point Tester(2008)

Summary This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is...

Standard: ASTM -- D93 model: SYD-261(2008) E-mail: robin@pro-trueview.com

Summary
  This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

I. Main technical features
1. This instrument is designed as per GB/T261 and ASTM D93.
2. The heating power is continuously adjustable. The power is shown visually by voltmeter.The temperature control mode
     is advanced and reasonable.
3. The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by
     many metering and detecting institutes.
 
II. Main technical specifications
1. Power supply:AC (220±10%)V, 50Hz.
2. Heating device::The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate::(1~12)℃/min;Controllable and adjustable.
4. Stirring rate: Procedure A: (90~120)RPM, Procedure B: (250±10)RPM
5. Oil cup:(1) Inner diameter: 50.7mm~50.8mm.
                     (2) Depth: 55.7mm~56.0mm 
                     (3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.
                     (4) Capacity of testing oil:about 70ml
6. Igniting device:(1) Igniting source: gas(or other civilian fuels,the same below)
                                   (2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Thermometers:Mercury-in-glass thermometer.Specifications are as below:
                                  (1)Scale -5℃~110℃, division 0.5℃。
                                  (2)Scale 20℃~150℃, division 1℃。
                                  (3)Scale 90℃~370℃,division 2℃。
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
10.Maximum power consumption:650W

Full set and technical documents
1. Full set

No. Name Unit Quantity Remark
1 Main unit Set 1  
2 Thermometer -5℃~110℃ each scale division is 0.5 ℃; Piece 1 As per GB/T 261-2008
3 Thermometer 20℃~150℃ each scale division is 1.0 ℃; Piece 1
4 Thermometer 90℃~370℃ each scale division is 2 ℃; Piece 1
5 Soft shaft Piece 1  
6 Silica gel tube φ3  0.5 m Piece 3 1 is spare
7 Power supply wire (250 V 6A) Piece 1  
8 Fuse 5A (Ф5×20) Piece 2  
9 Thermometer adapter Set 1  
10 Thermometer liner band (cut suitable length of liner band to wrap the lower end of the thermometer so that the thermometer is just inserted into the thermometer adaptor) Piece 5  
2. Technical documents
(1) Operation Manual                                              1 piece
(2) Quality Certificate                                              1 piece
(3) Repair Guarantee                                               1 piece