Summary The instrument is designed and made as per T0625 Asphalt Brookfield Rotational Viscosity Test (Brookfield Viscometer Methods) in the Industry standard of Peoples Republic of China JTJ052 Specifications and Test Methods of Bitumen an...
Summary
The instrument is designed and made as per T0625 “Asphalt Brookfield Rotational Viscosity Test (Brookfield Viscometer Methods)” in the Industry standard of People’s Republic of China JTJ052 Specifications and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering. It is the upgrade one of NDJ-1B and NDJ-1C Rotational Viscometers. It is suitable to determine the absolute viscosity of Newtonian liquids and the apparent viscosity of Non-Newtonian liquids.
It adopts advanced mechanical design and manufacturing techniques, and uses a microprocessor for temperature control, data collection and data process.The LCD is a white backlight, ultra-bright LCD. It is also equipped with a micro-printer. Test dada can be shown on the LCD and/or printed out from a printer.The instrument has a RS232 communication port to connect with a computer.
It is sensitive, reliable, generous and easy to be operated. It is widely used for determining viscosities of asphalt, hot melt adhesive, paraffin, high polymer, and other liquids.
II. Main technical specifications
1. Measurement range: 100 mPa•s~2×106mPa•s (If use the N0.30 spindle, the measurement range can be extended to
4×106mPa•s);
2. Spindle: No.21. 27. 28 and 29 spindles (The No.30 spindle is optional).
3. Speed: 0.5, 1, 2, 5, 10, 20, 50 RPM
4. Measurement error: ±2% (F•S).If use the No.30 spindle, it will be ±3% (F•S).
5. Temperature control range: 45℃~200℃;
6. Temperature control accuracy: ±0.1℃;
7. Cubage of sample cylinder: 20 ml;
8. Power supply: AC 220 V±10%,50Hz;
9. Ambient temperature: 5℃~35℃ (If it is near the controlling temperature, please use a air conditioner to make sure that
the ambient temperature is about 5 ℃ lower than the controlling temperature of heater.
10. Relative humidity: ≤80%
11.Printing output:needle printer
12.Comunication port:RS232 port
III,Optional accessories
1.NDJ-1D Brookfield Viscometer and Computer communication software(CD)
2. 300℃ high temperature heating furnace
3. 30# rotator
No. | Name | Unit | Quantity |
1 | Head of viscometer | Set | 1 |
2 | Pedestal of instrument (having three level adjustment bolts) | Set | 1 |
3 | Toothed rod | Piece | 1 |
4 | Auxiliary controlling case (containing a temperature controller and a micro-printer) | Set | 1 |
5 | Heater | Piece | 1 |
6 | Spindle (No.21, 27, 28 and 29) | Piece | 1 for each |
7 | Connection hook and transition bolt | Piece | 1 for each |
8 | Power supply wire (250 V 6 A) | Piece | 1 |
9 | Serial port wire | Piece | 1 |
10 | Heater connection wire | Piece | 1 |
11 | Sensor wire | Piece | 1 |
12 | Sample cylinder, sample cylinder holder, sample cylinder cover, special forceps | Piece | 1 for each |
13 | Fuse (Φ5×20) 5 A | Piece | 3 |
14 | CD for communication with a PC | Piece | 1 |