Have any questions? robin@pro-trueview.com 0086-18007322239

You in this column



Direct Reading Spectrometer

Summary TS-W2 is designed specificallyfornonferrous metal. Itisreliableanalyzerwhen it comes tononferrousmetals analysis. It is our entry level model which is available as a dedicated single-base unit as well as a versatile multi-base syst...

Standard: model: TS-W2 E-mail: robin@pro-trueview.com

Summary
TS-W2 is designed specifically for nonferrous metal. It is reliable analyzer when it comes to nonferrous metals analysis. It is our entry level model which is available as a dedicated single-base unit as well as a versatile multi-base system. The overall optical design has been enhanced, and with improvements in CCD technology used to further improve the performance of the TS-W2 while retaining the major benefit of earlier units. This gives the TS-W2 the ability to analysis elements across the complete range of nonferrous metals and alloys.

Application
TS-W2 optical emission spectrometers(spark OES) is used for applications in nonferrous metal elemental analysis for science and industry like Metallurgy, Foundry, Mechanical Engineering, Scientific Research, Product Inspection, Automobile, Petrochemical Engineering, Shipbuilding, Nonferrous Metallic Processing and Recycling. It is including full element analysis range, but at same time the element analysis amount can be bespoke.

Detection Matrices:
1.Aluminium(Al) and its alloys
2.Copper(Cu) and its alloys
3.Cobalt(Co) and its alloys
4.Magnesium(Mg) and its alloys
5.Zinc(Zn) and its alloys
6.Lead(Pb) and its alloys
7.Tin(Sn) and its alloys
8.Small sample, special size sample and wire detection

Parameters

Item

Index

Optical system

The Paschen Runge construction full vacuum type optics system

Wavelength coverage

200nm~560nm

Focal length

150mm

Detector    

High-performance CCD Array

Type of Lamp-house

New digital adjustable light, high energy precombustion technology(HEPS)

Discharge frequency  

100-1000Hz

Discharge current

Maximum  400A

Testing time  

According to the sample type,generally about 25s

Electrode  

Tungsten material injection electrode

Analytical gap

The sample analysis of clearance:3.4mm

Vacuum system

The vacuum automatic control and monitoring software

Room temperature

34℃±0.3℃

Argon purity requirements

99.999%

Argon gas inlet pressure

0.5MPa

Argon flow  

Stimulate the flow around 3.5L/min

Working temperature

10℃~35℃

Working humidity     

20%~85%

Working power supply  

220V  AC   50/60Hz