Introduction: ● Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function settin...

Standard: model: TS-SI517 E-mail: robin@pro-trueview.com

Introduction:

● Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc.
● There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
● Sodium electrode range : 1~7 pNa (10-1~10-7 mol/L)
● Equips sodion electrode, reference electrode and temperature electrode.
● Can switch 4 kinds of concentration unit : pX, mol/L, mg/L and ppm
●Meter has the only product serial number.
● Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps.

Standard Kit Incudes :

1. Model MP517 sodium ion concentration meter 1set
2. Model 602 flexible electrode holder 1pc
3. Model 901 intelligent stirrer 1set
4. B628 stir bead 3pc
5. Model 6801 sodium ion electrode 1pc
6. Model 6212-M reference electrode 1pc
7. Model MP500 temperature electrode 1pc
8. pNa1.00 standard solution (100 mL) 2 btls
9. 10-1 mol/L CsCl reference solution (30mL) 1pc
10. 9V power adapter (meter use) 1 pc
11. 16V power adapter (stirrer use) 1 pc
12. AA battery 4 units
13. RS-232 communication cable 1pc
14. MP517 communication software CD 1 unit
15. Operation manual 1 unit
16. Brief operation instruction 1unit
17. Packing List 1pcs

Optional  Accessories:

Accessory Categry
Description
Specifications
Ion electrode
7801 Sodium ion electrode
Used to test the concentration of sodium ion,BNC plug
CA501 Calcium composite electrode
used for testing Calcium concentration,BNC plug
Calcium electrode probe
Used with CA501 electrode
F502 Fluoride electrode
Used to test Fluoride concentration,BNC plug
CL502 Chloride electrode
Used to test the concentration of chloride ion,BNC plug
BR502 Bromide electrode
Used to test the concentration of bromide ion,BNC plug
I502 Iodide Electrode
Used to test the concentration of iodide ion,BNC plug
CU502 Copper electrode
Used to test the copper concentration,BNC plug
K502 Potassium electrode
Used to test the concentration of potassium ion,BNC plug
NO502 Nitrate electrode
Used to test the concentration of nitrate ion,BNC plug
NH501 Ammonia electrode
Used to test the ammonia concentration,BNC plug

Reference Electrode

6211 Reference electrode

Suitable for routine measurements, banana plugs.

6212 Reference electrode

Equipped with the 7801 sodium ion electrode, banana plugs

6213 Reference electrode

The first and second salt bridge solution can be chosen, for all measurement occasions, banana plugs.

6215 Reference electrode

Most ion electrode for supporting the use, banana plugs

Temperature Electrode
MP500 Temperature electrode
Stainless steel housing, fast response, high accuracy, RCA plugs
Ion standard solution
 
10-1 mol/L Na+ Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L Ca2+ Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L F- Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L Cl- Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L Br- Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L I- Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L K+ Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L Cu2+ Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L Ammonium ion Standard Solution
500mL/250mL/100mL(bottle)
10-1 mol/L NO3 Standard Solution
500mL/250mL/100mL(bottle)
Electrode soaking
pH(ORP)Combination Electrode Soaking Solution
500mL/250mL/100mL(bottle)
10-5 mol/L Sodium ion electrode soaking Solution
Equipped with 7801Sodium electrode . 500mL/250mL/100mL(bottle)
Electrode add liquid

3.5mol/L KCl(AgClSaturated) reference solution

250mL/50mL/30mL(bottle)

1mol/LPotassium nitrate (KNO3) reference solution

For chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle)

1mol/L Sodium chloride (NaCl) reference solution

Test for potassium, and equipped with 6215 reference electrode,250mL/100mL/30mL(bottle)

0.1mol/L Cesium chloride (CsCl) reference solution

Test for sodium,and equipped with 6212 reference electrode,250mL/100mL/30mL(bottle)

Ammonia electrode inner solution

Test for ammonium ion, and equipped with NH501 ammonia electrode,250mL/100mL/30mL (bottle)

Calciumelectrode inner solution

equipped with CA501 Calcium electrode, 250mL/100mL/30mL(bottle)

Electrode add liquid
3.5mol/L KCl(AgClSaturated) reference solution
500mL/250mL/100mL(bottle)
1mol/LPotassium nitrate (KNO3) reference solution
For chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle)
1mol/L Sodium chloride (NaCl) reference solution  
Test for potassium, and equipped with 6215 reference electrode,250mL/100mL/30mL(bottle)
0.1mol/L Cesium chloride (CsCl) reference solution 
Test for sodium,and equipped with 6212 reference electrode,250mL/100mL/30mL(bottle)
Ammonia electrode inner solution 
Test for ammonium ion, and equipped with NH501 ammonia electrode ,250mL/100mL/30mL(bottle)
Calcium electrode inner solution
equipped with CA501 Calcium electrode, 250mL/100mL/30mL(bottle)
Electrode holder

Model 602 Flexible Electrode Holder

Nice appearance of the arc-type bracket, you can turn 360 degrees and vertical lift

Model 601Stirring Type Electrode Holder

The electrode holder and magnetic stirrer combination of new products.

Model 600 Electrode Holder

Cheap simple electrode holder