Introduction: ●Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion). ●Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measure...
Introduction:
●Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion). |
●Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use. |
●Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc. |
● Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France)、ºdH (Germany)and ºeH(UK) from WH-Link communication software. |
●Equipped with B1、B2 and B3 calibration solution. |
●Equipped with WH-Link communication software, connect testing data of meter to computer. |
Water Hardness
|
Temp. compensation
Calibration Solution
Calibration Mode
|
(0 ~ 10)mmol/L; (0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO); (0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler); (0 ~ 70)ºeH (England Degree)。
0.01 and 0.1 water hardness units
±5% FS
(5 ~ 50)℃((automatic))
B1 Calibration Solution — 2.00×10-2 mmol/L
B2 Calibration Solution — 2.00×10-1 mmol/L
B3 Calibration Solution — 2.00 mmol/L
(B3Calibration Solution also can be used for the soaking solution of electrode)
(a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.
(b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality.
|
Temperature
|
Measuring range
Resolution
Accuracy
|
0 ~ 60℃
0.1℃
±0.5℃
|
Other Technical Parameter
|
Data storage
Content Storage Communication Connector Power Dimension and weight
Quality and safe certificate
|
128 groups
serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.
RS232
DC9V (160×190×70)mm/750g IISO9001:2000 and CE |
working conditions
|
Ambient temperature
ambient humidity
|
(5~35)℃
≤85%RH
|
1. Model YD300 water hardness meter |
1set |
2.Model 601-F water hardness electrode( With two measruing heads and one screw plug ) |
1pc |
3. Model 602 Flexible electrode holder |
1pc |
4.250mL water hardness calibration solution (B1, B2 and B3) |
1btl/each |
5.20mL test cup |
4pcs |
6. Test cup pedestal |
1pc |
|
|
7. WH-Link communication software |
1 pc |
8. RS-232 communication cable | 1pc |
9. Operation manual | 1book |
Accessory Category |
Description |
Specification |
Water hardness electrode |
601-F water hardness electrode |
Suited for measurement of total concentration of calcium ion and magnesium ion, match YD200 meter, BNC+RCA connector |
|
||
Water hardness calibration solution |
Water hardness calibration solution B1 |
2.00×10-2 mmol/L,500mL/250mL/100mL(bottle) |
Water hardness calibration solution B2 |
2.00×10-1 mmol/L,500mL/250mL/100mL(bottle) |
|
Water hardness calibration solution B3 |
2.00 mmol/L,500mL/250mL/100mL(bottle) |
|
|
Plasic test cup |
Specification:20mL |
Test cup base |
Place test cup on the base |