Multiparameter portable water quality meter contains the 8 measurement modes. The meter is used for measuring the pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen of the samples. pH Mode: Portable mul...
Multiparameter portable water quality meter contains the 8 measurement modes. The meter is used for measuring the pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen of the samples.
pH Mode:
• Portable multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer group (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode diagnosis with pH slope and offset display.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes provide the reliable ORP measurements.
Ion Mode:
• 2 to 5 points calibration, containing the 8 concentration points can be selected.
• Automatically recognizes the ion selective electrode, does not need to specify type of ion.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units include the ppm, mg/L and mol/L.
Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration, automatically recognizes the conductivity standard solutions.
• Selectable cell constant (0.1/1/10), reference temperature (20°C/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations ensure the reliable DO measurements.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Alarm prompts user to calibrate the meter regularly.
• Stability indicator shows when a measurement is recognized as stable.
• Auto-Hold feature senses and locks the measurement endpoint.
• Battery indicator shows the remaining battery capacity.
• Auto-Power Off effectively conserves battery life.
• Calibration report provides the details of the calibration standard and electrode slope.
• Setup menu allows setting the 15 parameters, including the number of calibration points,
stability criteria, temperature unit, etc.
• Reset feature automatically resumes all settings back to factory default options.
• Expanded memory stores and recalls up to 500 data sets.
• Stored readings can be transferred into the computer by USB communication interface.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that use the
meter smoothly.
Specifications:
Model |
TS-PT900 |
|
pH |
||
Range |
-2.000~20.000pH |
|
Accuracy |
±0.002pH |
|
Resolution |
0.1/0.01/0.001pH, selectable |
|
Calibration Points |
1 to 5 points |
|
pH Buffer Options |
USA, NIST, DIN or Custom |
|
mV |
||
Range |
-1999.9~1999.9mV |
|
Accuracy |
±0.2mV |
|
Resolution |
0.1/1mV, selectable |
|
Calibration Points |
1 point |
|
Measurement Modes |
Relative or Absolute mV |
|
Ion |
||
Range |
0.001~19999ppm, mg/L, mol/L (Depond on the range of ISE) |
|
Accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
|
Resolution |
0.001/0.01/0.1/1 |
|
Calibration Points |
2 to 5 points |
|
Calibration Solutions |
0.001/0.01/0.1/1/10/100/1000/10000ppm, mg/L, mol/L |
|
Conductivity |
||
Range |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
|
Accuracy |
±0.5% F.S |
|
Resolutions |
0.01/0.1/1 |
|
Calibration Points |
1 to 5 points |
|
Calibration Solutions |
10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm |
|
Temperature Coefficient |
0.0~10.0%/°C |
|
Compensation Modes |
Linear or Pure water |
|
Cell Constant |
K=0.1, 1, 10 or Custom |
|
Reference Temperature |
20°C or 25°C |
|
TDS |
||
Range |
0~10.00, 100.0, 1000ppm, 10.00, 100ppt (Max. 200ppt) |
|
Accuracy |
±1% F.S |
|
TDS Factor |
0.1~1.0 (Default 0.5) |
|
Salinity |
||
Range |
0.00~80.00ppt, 0.00~42.00psu |
|
Accuracy |
±1% F.S |
|
Measurement Modes |
Practical salinity (psu) or Natural seawater (ppt) |
|
Resistivity |
||
Range |
0.00~20.00MΩ |
|
Accuracy |
±1% F.S |
|
Resolution |
0.01/0.1/1 |
|
Dissolved Oxygen |
||
DO Range |
0.00~20.00mg/L |
|
Accuracy |
±0.2mg/L |
|
Resolution |
0.1/0.01mg/L, selectable |
|
% Saturation Range |
0.0~200.0% |
|
Accuracy |
±2.0% |
|
Resolution |
0.1/1% |
|
Calibration Points |
1 or 2 points |
|
Pressure Correction |
60.0~112.5kPa, 450~850mmHg |
|
Salinity Correction |
0~50g/L |
|
Temperature |
||
Range |
0~105°C, 32~221°F |
|
Accuracy |
±0.5°C |
|
Resolution |
0.1°C |
|
Calibration Points |
1 point |
|
Temperature Units |
°C or °F |
|
General |
||
Temperature Compensation |
0~100°C, 32~212°F, Manual or Automatic |
|
Data Hold |
Manual or Automatic endpoint detection |
|
Stability Criteria |
Low or High |
|
Calibration Due Alarm |
1 to 31 days |
|
Power Off |
Manual or Automatic (10, 20, 30 minutes) |
|
Reset Function |
Yes |
|
Memory |
Stores up to 500 data sets |
|
Output |
USB communication interface |
|
Connector |
BNC, 6-pin mini plug |
|
Display |
LCD |
|
Power Requirements |
3×1.5V "AA" batteries |
|
Battery Life |
Approximately 150 hours (Turn off the backlit) |
|
Dimensions |
170(L)×85(W)×30(H)mm |
|
Weight |
300g |