Infrared Sulfur Analyzer
50 Samples loaded once.
Highlights:
High Automation, high test efficiency.
①Analysis time / sample is<2 minutes. Samples can be placed in process of test.
②50 autoloader design, high automation, no need attendance in the whole process. Manual sample introduction is also available.
③Patented technology of combustion gas curtain effectively ensures thorough combustion of sample and no emission of gas. Safe and environmental friendly.
④Filter wool can be replaced automatically, no damage to combustion tube and furnace.
⑤Easy and convenient for gas leakage check, operators only need to click on the software.
Humanization Design with stable performance.
①Tailored boat shaped crucible can be placed at random.
②Automatic identification of crucibles by locator card, no need coding in advance.
High Precision.
①Specially designed high temperature combustion tube with secondary combustion function, makes sure the samples combust thoroughly.
②Self-developed ultra low drift infrared cell guarantees that only one drift in a working day is enough for accurate test.
Intelligent control.
①Easy to use Windows-based software: It only needs to click the mouse after weighing and placing the samples.
②Easy data handling, real time data can be transmitted by internal network.
③With Ethernet bus communication technology, one PC controls several analyzers.
④Capable of connecting with network and balance by RS232 interface.
Specifications:
Description |
TS-IS350 |
Test Method |
Infrared Absorption |
Sulfur Determination Range |
0.01% - 50%(can be extended to 100%) |
Standards |
GB/T 25214-2010 ISO 19579:2006 ASTMD 4239-2012 |
Sulfur Resolution |
0.001% |
Analysis Time/sample |
< 2 min |
Preheating Time |
≤150min |
Max. Quantity of sample |
50 |
Sample Weight |
80 – 500mg(100mg Recommended) |
Furnace Temp |
1250℃ - 1350℃ |
Heating Elements |
Silicon Carbide |
Temp. Control Precision |
±1℃ |
Temperature Sensor |
Thermocouple |
Power Requirement |
220V(-15% ~ 10%)50/60Hz |
Max. Power |
4kW |
Gas Requirement |
99.5% purity oxygen≥1MPa |
Gas pressure |
Oxygen(0.28±0.01)MPa Total Air Flow≥1MPa |
Sample Introduction and Discarding |
Automatic |
Gas Flow Checking |
Rotor flow meter adopted Gas flow by visual check |
Chemical Reagents |
Dehydrite |
Humidity |
≤85% |
Ambient Temperature |
(15~30)℃ |
Operational Control |
Windows®-based software on external PC |
Operation Cost |
Oxygen consumption lowered by intelligent gas supplying system.Desiccant: Dehydrite which is of higher cost |
Dimensions |
860*670*630mm |
Weight |
165kg |
Advance Calculation |
Yes |
Analysis Report |
Yes |
Statistics Report |
Yes |
System Monitor |
Yes |