Agricultural Instruments

Fat Meter Analyzer

model: TS-FM101
Standard:
E-mail: robin@pro-trueview.com


Summary:

TS-FM101 is based on Soxhlet extraction depth optimization and improvement operating system, it pursues beauty, simplicity, high efficiency and TS-FM101 instrument hardware design inside and outside echo, complement each other, beautiful interface, simple appearance, set immersion, extraction, Heating, condensation, solvent recovery, drying and other functional improvements, so that you in the daily use, always feel the excellent experience brought by TS-FM101. 

Product characteristics:

Fully sealed electric heating with arbitrary temperature adjustment at room temperature (200 ℃)
Graphical interface, easy to use, convenient for beginners to learn 
Solvent recovery and storage
Non-cock design: avoid leakage and glass pipe damage caused by rotating cock, effectively improve sealing and service life 
Temperature limit protection: temperature upper limit can be set, when the actual temperature exceeds the upper limit, the instrument automatically alarm and stop heating 
Automatic 6-stage heating: the temperature and heat preservation time can be set for 6 consecutive stages, and the instrument will be completed automatically in sequence 
Drying function: no need to transfer the sample to the oven directly on the instrument
New era simple style appearance of engineering plastic shell, surface sprayed anticorrosive material

Technical parameters:(★ said Company Features)

1.Measure Range: Crude fat content ≥ 0.1% ;
2.Measure quantity: 6 samples at same time;
3.Solvent reclaim rate ≥ 80%;
4.★Methods: automatic recovery of solvent recovery and storage
5.Precision: Relative difference ≤ 3%, Parallel difference ≤ 0.3%;
6.Reclaim rate: ≥ 99% (backflow Speed 120 drop/minute, Cooling water temperature ≤ 30℃); 
7.★Heating: Aluminum Alloy plate, electric heating;
8.★Seals: PTFE seal;
9.★Display: color screen LCD; holding time countdown;
10.★Other features: 6 stages of heating, drying
11.Temperature control range: Room temperature~200℃;
12.★Temperature control precision: ±0.3℃;
13.Working power: 220V±10%, 50~60HZ;
14.Rated power: 500W;
15.Size:640×435×700(mm);
16.Weight:35kg;
 


Return

Shanghai Trueview Scientific Instrument Co. LTD
Phone: 0086-18007322239 (Robin)
Fax: 0086-734-8770418
Cell: 0086-15367067787
Wechat: 0086-18007322239
Email: robin@pro-trueview.com
Add: Room 118, Block 21, No.1-42, Lane 83 ,Hongxiang North Road, Wanxiang Town, Pudong New Area, Shanghai City, China