Coal Analysis Instruments

Bomb Calorimeter

model: TS-BC6000
Standard: ASTM -- D5865
E-mail: robin@pro-trueview.com


Application:

TS-BC6000 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material.
Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering, full test ...
Optional support stand, customer can choose either benchtop or vertical type

Highlights:

Optimized design, fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering, full test process is less than 10 minutes.

①Unique bucket water circle system, which can determine water volume for each testing automatically. New stainless steel oxygen bomb can be easily assembled and disassembled. High stirring efficiency by propeller, faster heat transfer of oxygen bomb, testing time is greatly reduced.
②Unique automatic press type oxygen filling & releasing design, no blockage, much more stable than traditional automatic calorimeter.
③Built-in intelligent water tank with heating and cooling function, water temperature can keep constant, non-stop working available.
④High automation: bomb raising & lowering, oxygen filling & releasing, determination of bucket water volume and control of water 
temperature and test can be finished automatically. 

Good environment adaptability, precise, accurate and reliable rest result

①Helix tube multipoint isothermal technology, create a controllable and stable internal environment (consists of jacket and jacket lid, 
temperature difference<0.1℃),stop the interference of external environment (such as air flow, temperature) to bucket, test result is 
reliable.
②Independent jacket and bucket water system. After the test, bucket water automatically flow back into water tank, no affection between inlet and outlet of bucket water and jacket water. Jacket water temperature is stabilized. 

Accurate and reliable test result

①Larger heat capacity make the testing result is more accurate and reliable.
Reasonable structure, reliable operation, safe and environment friendly
①With self-diagnostic function, malfunction can be detected accurately, easy to maintain.
②Unique crucible support design, convenient to use.

Specification:

Description

TS-BC6000

Analysis Time

Analysis Time: <8min Full Test Process: <10min

Temperature Resolution

0.0001K

Precision(RSD)

≤0.1%

Heat Capacity Stability

≤0.2% within three months

System Structure

Benchtop / Vertical

Conformance with Standard

ASTM D 5865,ISO 1928 GB/T 213-2008

Test per Hour

6

Bomb volume

250ml

Calorimeter Type

Isoperibol

Oxygen Filling

Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering

Bomb Washing

Manual

Max. Bomb pressure

20Mp

Bomb Identity

Yes

Gas Requirement

99.5% Oxygen

Water Requirement

Distilled  Water

Energy Measurement Range

0~50000J

Bucket Filling

Automatic

Constant Volumetric Tank with Temp Control Device

Bucket determine water volume automatically

Independent Bucket and Jacket Water System

Yes

Stirring Method

Propeller

Power Inverter

No

Reproducibility based on analysis of 1g Benzoic Acid

0.10%

Average Temperature Increase

2℃

Temperature Measurement

PT1000

Working Temperatures

≤32℃

Cooling method

Refrigerating Device

Network

Yes

Power

220V (-10% +10%)50/60Hz

Max.Power

0.6KW

Dimension

Main body: 440*550*460 Water tank: 390*550*440

Weight

50kg

Advance Calculation

Yes

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes



Return

Shanghai Trueview Scientific Instrument Co. LTD
Phone: 0086-18007322239 (Robin)
Fax: 0086-734-8770418
Cell: 0086-15367067787
Wechat: 0086-18007322239
Email: robin@pro-trueview.com
Add: Room 118, Block 21, No.1-42, Lane 83 ,Hongxiang North Road, Wanxiang Town, Pudong New Area, Shanghai City, China
Copyright © 2018.Trueview Scientific All rights reserved.