Bomb Calorimeter
Application:
TS-BC6000 can be used to determine the calorific value of solid and liquid combustibles such as coal, coke, petroleum oil, cement black meal, biomass fuels as well as building material.
Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering, full test ...
Optional support stand, customer can choose either benchtop or vertical type
Highlights:
Optimized design, fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering, full test process is less than 10 minutes.
①Unique bucket water circle system, which can determine water volume for each testing automatically. New stainless steel oxygen bomb can be easily assembled and disassembled. High stirring efficiency by propeller, faster heat transfer of oxygen bomb, testing time is greatly reduced.
②Unique automatic press type oxygen filling & releasing design, no blockage, much more stable than traditional automatic calorimeter.
③Built-in intelligent water tank with heating and cooling function, water temperature can keep constant, non-stop working available.
④High automation: bomb raising & lowering, oxygen filling & releasing, determination of bucket water volume and control of water
temperature and test can be finished automatically.
Good environment adaptability, precise, accurate and reliable rest result
①Helix tube multipoint isothermal technology, create a controllable and stable internal environment (consists of jacket and jacket lid,
temperature difference<0.1℃),stop the interference of external environment (such as air flow, temperature) to bucket, test result is
reliable.
②Independent jacket and bucket water system. After the test, bucket water automatically flow back into water tank, no affection between inlet and outlet of bucket water and jacket water. Jacket water temperature is stabilized.
Accurate and reliable test result
①Larger heat capacity make the testing result is more accurate and reliable.
Reasonable structure, reliable operation, safe and environment friendly
①With self-diagnostic function, malfunction can be detected accurately, easy to maintain.
②Unique crucible support design, convenient to use.
Specification:
Description |
TS-BC6000 |
Analysis Time |
Analysis Time: <8min Full Test Process: <10min |
Temperature Resolution |
0.0001K |
Precision(RSD) |
≤0.1% |
Heat Capacity Stability |
≤0.2% within three months |
System Structure |
Benchtop / Vertical |
Conformance with Standard |
ASTM D 5865,ISO 1928 GB/T 213-2008 |
Test per Hour |
6 |
Bomb volume |
250ml |
Calorimeter Type |
Isoperibol |
Oxygen Filling |
Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
Bomb Washing |
Manual |
Max. Bomb pressure |
20Mp |
Bomb Identity |
Yes |
Gas Requirement |
99.5% Oxygen |
Water Requirement |
Distilled Water |
Energy Measurement Range |
0~50000J |
Bucket Filling |
Automatic |
Constant Volumetric Tank with Temp Control Device |
Bucket determine water volume automatically |
Independent Bucket and Jacket Water System |
Yes |
Stirring Method |
Propeller |
Power Inverter |
No |
Reproducibility based on analysis of 1g Benzoic Acid |
0.10% |
Average Temperature Increase |
2℃ |
Temperature Measurement |
PT1000 |
Working Temperatures |
≤32℃ |
Cooling method |
Refrigerating Device |
Network |
Yes |
Power |
220V (-10% +10%)50/60Hz |
Max.Power |
0.6KW |
Dimension |
Main body: 440*550*460 Water tank: 390*550*440 |
Weight |
50kg |
Advance Calculation |
Yes |
Analysis Report |
Yes |
Statistics Report |
Yes |
System Monitor |
Yes |