Lab pH,Ion Concentration,Conductivity and Dissolved Oxygen M
Introduction:
● Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc. |
● There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode. |
●Automatically recognize 13 kinds of pH buffer solution. User can choose anyone from four series of standard buffer solutions: Europe & USA series, NIST series, CHINA series and Self-defined series. |
●High purified water and ammonia added purified water pH measuring mode can be set up, especially suitable for electric power and petrochemical industry |
● With EH redox potential measuring mode can directly display ORP value which against standard potential of hydrogen electrode. |
● Automatically recognize 8 kinds of conductivity standard solution. User can choose anyone from two series of solutions: Europe & USA series and China series. |
● Adopt advanced and original conductivity measurement technology, use 1 pc of conductivity electrode (K=1), it can meet measuring accuracy requirement for range within 0.5μS/cm ~ 200mS/cm by using only one-point calibration. |
● Automatically select conductivity measurement range, when measuring high pure water, equipment automatically enter into temperature compensation of nonlinear model, especially for electricity, microelectronics and the pharmaceutical industry requirements. |
● Equips new type of DO electrode which has function of automatic temperature compensation and automatic salinity compensation as well as automatic air pressure compensation inside meter to make DO measuring mode has temperature, air pressure and salinity automatic compensation, easy to use, accurate to measure. |
● Polarogram type DO electrode has special electrode calibration cap. Only needs 3 to 5 minutes for electrode polarization. Electrode adopts combination diaphragm cap which very convenient to use. Each DO electrode equips with three spare diaphragms caps. |
●There are 10 kinds of common ions can be selected in the ion concentration measuring mode, user also can self-define other ions. |
●Can switch 4 kinds of concentration unit : pX, mol/L, mg/L and ppm |
● Meter has the only product serial number. |
●Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps. |
Specifications:
pH
|
Measuring range
Resolution
Accuracy
Input current
Input impendance
Stability
Temp. compensation range
|
(-1.999 ~ 19.999)pH
0.1/0.01/0.001 pH
Meter:±0.002 pH, connect meter with electrode:±0.01pH
≤1×10-12 A
≥3×1012 Ω
±0.002 pH/3h
(0 to 100) ℃(automatic or manual)
|
mV
|
Measuring range(mV/ORP/EH)
Resolution
Accuracy
|
-1999.9mV ~ 0 ~ 1999.9mV
0.1mV
±0.03% FS
|
Ion Concentration
|
Measuring range
Display unit
Accuracy
Temp. compensation range
|
0.00 ~ 14.00 pX
pX、mol/L、mg/L、ppm
Meter:±0.5 % reading(monovalent), ±1.0 % reading (bivalent)
0 to 60 ℃(automatic or manual)
|
Conductivity
|
Measuring range
Resolution
Accuracy
Temp. compensation range
Electrode constant
Reference temperature
|
Conductivity:(0.00~20.00)μS/cm (20.0~200.0)μS/cm
(200~2000)μS/cm (2.00~20.00)mS/cm
(20.0~200.0)mS/cm (200~2000)mS/cm(K=10)
Resistivity:(0 ~ 100)MΩ·cm
TDS: (0 ~ 100)g/L
Salinity: (0 ~ 100)ppt
0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm
Meter:±0.5% FS,connect meter with electrode:±0.80% FS
(0 ~ 50)℃(automatic )
0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1
25℃、20℃ and 18℃
|
Dissolved Oxygen
|
Measuring range
Resolution
Accuracy
Response time
Residual current
Temp. compensation range
Salinity compensation range
Air pressure compensation
Automatic calibration
Electrode type
|
(0 ~ 40.00)mg/L(ppm) (0 ~ 200.0)%
0.1/0.01 mg/L(ppm) 1/0.1 %
Meter:±0.10 mg/L,connect meter with electrode:±0.40 mg/L
≤30 s(25℃, 90% response)
≤0.1 mg/L
(0 ~ 45)℃(automatic)
(0 ~ 45)ppt(automatic)
(80 ~ 105)kPa(automatic)
Air saturated by water; water saturated by air
Polarogram type
|
Temperature
|
Measuring range
Resolution
Accuracy
|
-10℃~ 110℃
0.1℃
5~ 60℃range:±0.4℃ other range:±0.8℃
|
Other Technical Parameters:
|
Data storage
Storage content
Power
Communication connector
Size and weight
Quality and safety certification
|
300 groups
Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time
DC9V/300mA
RS232
160 × 190 × 70mm/880g
ISO9001:2008, CE and CMC
|
Working Condition
|
Environment temperature
Environmental humidity
IP rating
|
5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade)
≤75%
IP54 Dustproof and waterproof
|
Standard Kit Incudes:
1. Model MP551 pH/mV/ISE/Cond/DO meter | 1set |
2. Model 602 flexible electrode holder | 1pc |
3. Model 901 intelligent stirrer | 1set |
4. 201T-M plastic pH/ATC three-in-one combination electrode | 1pc |
5. 2503-C glass pH combination electrode | 1pc |
6. MP500 temperature electrode | 1pc |
7. 2401-M conductivity electrode | 1pc |
8. DO500 DO electrode | 1pc |
9. Model 6213 double salt bridge reference electrode | 1pc |
10. pH standard buffer solution(pH4.00、pH6.86、pH9.18/50ml) | 1btl/each |
11. 1413μS/cm conductivity standard solution (50 mL) | 2btls |
12. 9V power adapter (meter use) | 1pc |
13. 6V power adapter (stirrer use) | 1pc |
14. DO503 membrane cap (DO electrode use) | 3pc |
15. DO502 DO electrode inner solution (30 mL) | 1btl |
16. Cathode polishing paper | 2pcs |
17. B628 stirring bead | 3pcs |
18. AA battery | 4units |
19. RS-232 communication cable | 1pc |
20. MP551 communication software disk | 1pc |
21. Operation manual | 1unit |
22. Brief operation instruction | 1unit |
23. Packing List | 1pc |
Optional Accessories:
Accessory Categry
|
Description
|
Specifications
|
pH combination electrode |
201-C plastic combination pH electrode |
Suitable for routine pH measurements, widely used, BNC connector。 |
200-C plastic combination pH electrode |
Suitable for routine pH measurements, long continuous, high precision, BNC plug. |
|
206-C plastic combination pH electrode |
Smaller diameter electrode, suitable for small diameter container in a test, BNC connector |
|
201T-M plastic three-in-one combination pH electrode |
Simultaneous measurement of pH and temperature, automatic temperature compensation, BNC + RCA plugs. |
|
2501-C glass combination pH electrode |
For precise pH test, routine laboratory use, BNC plug. |
|
2503-C glass combination pH electrode |
For precise pH test, used to measure complex samples, BNC plug. |
|
2503D-C glass combination pH electrode |
For low-temperature solution and pure water pH measurement, BNC plug. |
|
2503G-C glass combination pH electrode |
Suitable for high temperature solution pH measurements, BNC plug |
|
2503S-C glass combination pH electrode |
For acid and high-temperature solution pH measurements, BNC plug. |
|
2015P-C plane combination pH electrode |
For the surface and trace solution pH measurement, BNC plug. |
|
Ion electrode
|
||
7801 Sodium ion electrode
|
Used to test the concentration of sodium ion,BNC plug
|
|
CA501 Calcium composite electrode
|
used for testing Calcium concentration,BNC plug
|
|
Calcium electrode probe
|
Used with CA501 electrode
|
|
F502 Fluoride electrode
|
Used to test Fluoride concentration,BNC plug
|
|
CL502 Chloride electrode
|
Used to test the concentration of chloride ion,BNC plug
|
|
BR502 Bromide electrode
|
Used to test the concentration of bromide ion,BNC plug
|
|
I502 Iodide Electrode
|
Used to test the concentration of iodide ion,BNC plug
|
|
CU502 Copper electrode
|
Used to test the copper concentration,BNC plug
|
|
K502 Potassium electrode
|
Used to test the concentration of potassium ion,BNC plug
|
|
NO502 Nitrate electrode
|
Used to test the concentration of nitrate ion,BNC plug
|
|
NH501 Ammonia electrode
|
Used to test the ammonia concentration,BNC plug
|
|
Reference Electrode |
6211 Reference electrode |
Suitable for routine measurements, banana plugs. |
6212 Reference electrode |
Equipped with the 7801 sodium ion electrode, banana plugs |
|
6213 Reference electrode |
The first and second salt bridge solution can be chosen, for all measurement occasions, banana plugs. |
|
6215 Reference electrode |
Most ion electrode for supporting the use, banana plugs |
|
Conductivity Electrode
|
DJS-0.1-M Pure water conductivity electrode
|
K=0.1 cm-1,Automatic temperature compensation, for testing the conductivity of high pure water, 4-pin plug
|
2401-M Glass conductivity electrode
|
K=1.0 cm-1,Automatic temperature compensation, precision laboratory test for conductivity, 4-pin plug.
|
|
2301-M Plastic conductivity electrode
|
K=1.0 cm-1,Automatic temperature compensation for laboratory and field testing, 4-pin plug.
|
|
2310-M Plastic conductivity electrode
|
K=10 cm-1,Automatic temperature compensation, used to test seawater and concentrated salt water, etc., 4-pin plug
|
|
Glass flow cell
|
Equipped with DJS-0.1-M electrode
|
|
DO Electrode
|
DO500 DO electrode
|
Polarographic-type DO electrode,For laboratory and field using, 8-pin plug
|
DO Electrode attachment
|
DO503 DO electrode membrane cap
|
Combined membrane cap,Dedicated to the DO500 DO electrode, size: 3 / group
|
DO502 DO electrode electrolyte
|
Added electrolyte, dedicated to the DO500 DO electrode, specifications: 30mL/bottle
|
|
DO501 Cathode polishing paper
|
Polishing paper, dedicated to clean DO500 DO electrode cathode, Size: 2 / group.
|
|
ORP Composite electrode
|
301Pt-C Plastice ORP combination electrode |
ORP measurement for conventional, wide range of uses, BNC plug |
3501Pt –C Glass ORP combination electrode |
ORP measurement of routine laboratory, test stability, fast response, BNC plug |
|
Temperature Electrode
|
MP500 Temperature electrode
|
Stainless steel housing, fast response, high accuracy, RCA plugs
|
pH Buffer
|
pH4.00 buffer |
500mL/250mL/50mL(bottle) |
pH6.86 buffer |
500mL/250mL/50mL(bottle) |
|
pH7.00 buffer |
500mL/250mL/50mL(bottle) |
|
pH9.18 buffer |
500mL/250mL/50mL(bottle) |
|
pH10.01 buffer |
500mL/250mL/50mL(bottle) |
|
Ion standard solution
|
10-1 mol/L Na+ Standard Solution
|
500mL/250mL/100mL(bottle)
|
10-1 mol/L Ca2+ Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L F- Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L Cl- Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L Br- Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L I- Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L K+ Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L Cu2+ Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L Ammonium ion Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
10-1 mol/L NO3 Standard Solution
|
500mL/250mL/100mL(bottle)
|
|
Conductivity Calibration Solution
|
84 μS/cm Conductivity Calibration Solution |
500mL/250mL/50mL(bottle)
|
1413 μS/cmConductivityCalibration Solution |
500mL/250mL/50mL(bottle)
|
|
12.88 mS/cmConductivityCalibration Solution |
500mL/250mL/50mL(bottle)
|
|
146.6 μS/cmConductivityCalibration Solution |
500mL/250mL/50mL(bottle)
|
|
1408 μS/cmConductivityCalibration Solution |
500mL/250mL/50mL(bottle)
|
|
12.85 mS/cmConductivityCalibration Solution |
500mL/250mL/50mL(bottle)
|
|
Electrode soaking
|
pH(ORP)Combination Electrode Soaking Solution
|
500mL/250mL/100mL(bottle)
|
10-5 mol/L Sodium ion electrode soaking Solution
|
Equipped with 7801Sodium electrode . 500mL/250mL/100mL(bottle)
|
|
Electrode add liquid
|
3.5mol/L KCl(AgClSaturated) reference solution |
250mL/50mL/30mL(bottle) |
1mol/LPotassium nitrate (KNO3) reference solution |
For chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle) |
|
1mol/L Sodium chloride (NaCl) reference solution |
Test for potassium, and equipped with 6215 reference electrode,250mL/100mL/30mL(bottle) |
|
0.1mol/L Cesium chloride (CsCl) reference solution |
Test for sodium,and equipped with 6212 reference electrode,250mL/100mL/30mL(bottle) |
|
Ammonia electrode inner solution |
Test for ammonium ion, and equipped with NH501 ammonia electrode,250mL/100mL/30mL (bottle) |
|
Calciumelectrode inner solution |
equipped with CA501 Calcium electrode, 250mL/100mL/30mL(bottle) |
|
Electrode add liquid
|
3.5mol/L KCl(AgClSaturated) reference solution
|
500mL/250mL/100mL(bottle)
|
1mol/LPotassium nitrate (KNO3) reference solution
|
For chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle)
|
|
1mol/L Sodium chloride (NaCl) reference solution
|
Test for potassium, and equipped with 6215 reference electrode,250mL/100mL/30mL(bottle)
|
|
0.1mol/L Cesium chloride (CsCl) reference solution
|
Test for sodium,and equipped with 6212 reference electrode,250mL/100mL/30mL(bottle)
|
|
Ammonia electrode inner solution
|
Test for ammonium ion, and equipped with NH501 ammonia electrode ,250mL/100mL/30mL(bottle)
|
|
Calcium electrode inner solution
|
equipped with CA501 Calcium electrode, 250mL/100mL/30mL(bottle)
|
|
ORP standard solution
|
222 mV ORP Standard solution
|
250mL/100mL/50mL(bottle)
|
Electrode holder
|
Model 602 Flexible Electrode Holder |
Nice appearance of the arc-type bracket, you can turn 360 degrees and vertical lift |
Model 601Stirring Type Electrode Holder |
The electrode holder and magnetic stirrer combination of new products. |
|
Model 600 Electrode Holder |
Cheap simple electrode holder |