Automatic ELISA Systems
model: BE-65
Standard:
E-mail: robin@pro-trueview.com
Processing Speed:
All Tryte BE Model can pipette, shake and incubate on the same multifunctional microplate position in order to improve processing speed. Each incubator has its own temperature control. A lid is automatically placed onto the plate while incubating to avoid evaporation. Samles. Reagents, microlateds and tips can be continuously loaded.
Zero Carryover
This instrument use high quality disposable tips to effectively avoid carryover and ensure accurate results.
Intelligent buffer management system
Each washer can control up to 8wash channels for different wash buffers. Volumes are monitored. Each container is equipped with an IC-Card .containing information such as type of buffer etc.
Software Features:
Simple GUI. User are giede in a step by step procedure to prepare the worktable, select their assays and start the run. Bidirectional interface allows the integration into a LIMS For transferring job lists and results. Access control for different user levels . dynamic scheduling of assays allows for optimized throughput. Continuous loading of samples .reagents and additional plates and tips, history log file and comprehensive QC program, analyzing data in and between plates, L-J QC charts etc, multiple tests per plate, parallel sample distribution within a plate or over several plates , liquid level and clot detection. Maintenance protocols for daily and routine maintenance. Job lists, different testes can be assigned to each sample by either downloading the job list from LIMS or by creating job lists manully.
3D-simulation mode
The simulation mode allows you to visually check and verify your processes after setting up new assays and test methods.
Main Parameters:
Type/Model | BE- 65 | |
1 | Brand | TRYTE |
2 | Application | Automatic ELISA testing :including sample distribution,pipetting reagents,shaking,incubating,washing and reading |
3 | Robotic arms | 1 |
4 | Pipetting probes | 2 |
5 | Pipetting precision | 100ul≤2.5% |
6 | Pipetting accurate | 100ul≤±1.0% |
7 | Liquid level detection | Pressure induction |
8 | Clot detection | yes |
9 | sample positions | 96 |
10 | Barcode Reader | yes |
11 | Microplate positions | 4 |
12 | independent shaking | 4 |
13 | independent incubator | 4 |
14 | Incubation temperature | Ambient to 55°C |
15 | Incubation temperature precision | ±0.5℃ |
16 | Microplate washers | 1 |
17 | Washers head | 16-way manifold |
18 | Residual volume of wash buffer | <2ul per well |
19 | Microplate reader | 1 |
20 | Wavelength range | 340-750nm |
21 | Filterslides | 405nm、450nm、492nm、630nm |
22 | Reading time | <12S |
23 | Measurement range | 0.000-3.999 OD |
24 | Reading precision | ±0.005 OD |
25 | Reading accuracy | 0.001 OD |