Dehydrator
model: TS-TSQ1
Standard:
E-mail: robin@pro-trueview.com
Main Features:
◆Operator Interface of 15 inch color LCD touch screen
◆Enclosed Tissue treatment system with no pollution of gas leakage, to meet requirement of environmental protection.
◆Mode of Sample processing: Sample not move,Reagent move.
it can avoid the risk of power failure of machine, or other mechanical failure.
◆Timing Mode: Finishing time of tissue processing any day in the week can be set
◆Fuction of Protection System of Power Failure.Once main power restored, the previous protocols is automatically
resumed and continue to work in order.
◆10 Set of Programmes stored in the system and can be set for purpose.
◆Special design of Reagent Station makes the liquid totally back-flow to avoid any mixture and to extend using time of
reagent.
◆Patented design of cassette holder makes reagent and samples thoroughly contact with each other,it improves effection
of tissue processing and reduce working time.
◆Dual Purpose of processing: one key switch normal processing motion and Rapid processing motion
Rapid Processing motion stirred in day time finished in 3 hours,Normal Processing Motion stirred in the evening.
◆Device for Air pressure transfer: Formal air pressure transfer of several solenoid valves replaced by One single
mechanical structure replace formal in order to avoid high fault error.
◆Fuction for changing wax automatically:
Wax in No.1 Container wash into waste container,then,wax in NO.2 container goes into No.1 Container,then,No.3 goes
into No.2,and so on
◆Fuction of over temperature protection occured by accidental heating
◆Fuction for magnetic stirring which shorten time of tissue processing and make good processing effection.
◆Alarm and Screen display when finishing work.
◆Capacity of tissue processing: 400pcs cassette at most.
Technical Specifications:
◆Bottle amount : 12. 1 - 9 for dehydration reagent, 14 - 16 for cleaning agent
◆Nos of Reagent Station: 12
◆Tissue Processing Station: NO.1 to No.9 Station
◆Washing Station: No.14 to No.16 Station
◆Nos of Wax Tank: 3(No.10,12 and 13)
◆Nos of Working Station: 1
◆Capacity of Processing Station: 9Liters
◆Capacity of Reagent Station :6L
◆Temp.of Processing Station:
◆Medium is the solvent: ≤45℃
◆Medium is the Wax: 58℃-70℃
◆Operation pressure:<0.1Mpa
◆Wax temperature :58℃-70℃
◆Wax melt time not more than 3 hours
◆Power input:<1500VA+10%
◆Time for immerse: 0 - 99 hours 59 minutes
◆Working Voltage:220VAC±10%,50/60HZ
◆Time for Inflow Liquid: no more than 5Min
◆Time for Exclude Liquid: no more than 5Min
◆Stirring time: set randomly
◆Interval time for Stirring: set randomly
◆Operation mode: manual and automatic