Petroleum Instruments

Automatic Pensky-Martens Closed-Cup Flash Point Tester

model: SYD-261D-1
Standard: ASTM -- D93
E-mail: robin@pro-trueview.com


Summary
This instrument is designed and manufactured as per standards GB/T 261 Determination of Flash Point - Pensky-Martens closed cup method,American Material and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.According to the standard method,It could determine the flash point of flammable liquid,liquid with suspended particles,liquid tending to film under the test condition and other type liquids.The instrument is widely used in petroleum industry,railway,electricity,universities and research institutes etc. departments.

I. Main technical features
1.    Standards:GB/T 261,ASTM D93 
       According to GB/T 261,It could do A and B test.
       According to ASTM D93,It could do A,B and C test.
2.    Adopt the German brand High precision sensor,German quality IPC(Industrial Personal Computer),8 inch colorful
       touch LCD display,automatical heating,testing and igniting etc.functions.
3.    With the barometric pressure sensor, It can correct the influence of atmospheric pressure and calculate the correction
       automatically.
4.    Stir the sample with the stepping motor,stable rotate speed,high accuracy,completely meet the stirring rate of GB/T
       261 and ASTM D93 standards.
5.    Store 200 test results,print the results by the miniprinter,transform the data to LIMS system according to the self-
       development software---Sinopec Lab Information Management System.
6.    Gas supply design:1 solenoid valve to control the total gas source and 2 channels gas source adjusting needle
       valves.The total gas source valve could be opened or closed automatically,to ensure the gas safety.The gas source of
       the kindling and igniting head could be adjusted respectively to realize the best of both worlds.
7.    With the manual operation mode,It checks and simulates the work condition of the instrument various functions,to find
       the problem timely and solve the issue.

II. Main technical specifications
1.    Measurement range: 40~300℃
2.    Standards: GB/T 261 and ASTM D93
3.    Temperature measurement:High precision PT100
4.    Flash point measurement:Miniature thermocouple
5.    Heating rate:(5~6)℃/min GB/T 261 A、ASTM D93 A
                             (1~1.5)℃/min GB/T 261 B、ASTM D93 B
                             (3.0±0.5)℃/min  ASTM D93 C
6.  Heater: AC220V、0.5kW 
7. Stirring rate: (90-120)rpm(GB/T 261 A;ASTM D93 A) 
                             250rpm(GB/T 261 B;ASTM D93 B) 
                             (90-120)rpm(ASTM D93 C) 
8. Gas source: Liquefied petroleum gas,Dimethylmethane 
9. Power supply: AC220V 5A 50Hz 
10.Dimension:   384mm×418mm×328mm(L×W×H) 
11.Net weight:   Around 15kg 

Return

Shanghai Trueview Scientific Instrument Co. LTD
Phone: 0086-18007322239 (Robin)
Fax: 0086-734-8770418
Cell: 0086-15367067787
Wechat: 0086-18007322239
Email: robin@pro-trueview.com
Add: Room 118, Block 21, No.1-42, Lane 83 ,Hongxiang North Road, Wanxiang Town, Pudong New Area, Shanghai City, China
Copyright © 2018.Trueview Scientific All rights reserved.