Bituminous Instruments

Automatic Penetrometer(Low temperature)

model: SYD-2801I
Standard: ASTM -- D5
E-mail: robin@pro-trueview.com


Summary
1.The instrument is designed and made as per the standards GB/T4509 Standard Test Method for Penetration of
    Bitumen, T0604 Bitumen Penetration Test in the standard JTJ052-2000 Specifications and Test Methods of Bitumen
    and Bituminous Mixtures for Highway Engineering and ASTM D5.
2.The instrument is suitable to determine the penetration of highway bitumen, modified asphalt, as well as liquid
    petroleum asphalt or residue of emulsified asphalt after evaporation.
3.The penetration of bituminous materials is expressed as the distance that a 100 g±0.05 g standard needle vertically
    penetrates into the sample without measurable fraction in 5 s at a constant temperature bath of 25±0.1 ℃. It is used for
    evaluating the consistency of asphalt. The larger the penetration is; the thinner and softer the asphalt is.
4.The instrument can also be used for inspecting industry materials such as solid granule, powder, colloid, as well as
    food materials such as cream, glycine, etc. It has been widely used in the field of food industry, highway and traffic
    departments and other departments.

I.Main technical specifications
1.Measurement range: 0 penetration~600 penetrations;
2.Resolution: 0.1 penetration;
3.Timing range: 0s~60 s, and the error is less than ±0.1 s.
4.Heating power: 200 W;
5.Temperature controlling accuracy: 25±0.1 ℃ (Note: the ambient temperature should not be higher than 20 ℃);
6.Data saved: 30 groups;
7.Constant temperature bath: harden glass container
a.Bath volume:5.5L
b.Temperature range: (5.0~100.0)℃
c.Temperature accuracy: ±0.1℃
d.Total consumption:less 1800W
e.Outline dimension: 420mm×380mm×900mm(L*W*H)
f:Power supply: AC(220±10%)V,50Hz
8.Stirrer: a magnetic stirrer;
9.Standard needle: 2.5±0.05 g and it conforms to the requirements of GB/T4509 and T0604.
10.Shifting holder: It has two ways to adjust the height of standard needle, so it is convenient to let the needle tip just
      touch the sample surface.
11.Power supply: AC 220 V±10%, 50 Hz.
12.Outline dimension: 280mm×350mm×700mm(L*W*H)
Return

Shanghai Trueview Scientific Instrument Co. LTD
Phone: 0086-18007322239 (Robin)
Fax: 0086-734-8770418
Cell: 0086-15367067787
Wechat: 0086-18007322239
Email: robin@pro-trueview.com
Add: Room 118, Block 21, No.1-42, Lane 83 ,Hongxiang North Road, Wanxiang Town, Pudong New Area, Shanghai City, China
Copyright © 2018.Trueview Scientific All rights reserved.