Direct Reading Spectrometer
Summary
TS-W6 The most advanced Arc/Spark-OES with Ultimate Performance for Metal Analysis. It use full-digital technology to replace bulky photomultiplier tube (PMT) simulation technology and in the lead of international spectrometer technology. The adoption of vacuum optical chamber design, full-digital excitation light source, advanced CCD detectors, and high-speed data readout system equips the device with high properties, ultra-low limit of detection (LOD), long-term stability and repeatability. Its analytical precision reaches the world leading level. It is one of the major devices that applies to quality control, material brand recognition, material research and development in the metallic manufacturing, processing and smelting industry. This analyzer sets a new standard for R&D and process/quality control.
Application
TS-W6 optical emission spectrometers(spark OES) as one of the major devices that applies to quality control, material brand recognition, material research and development in the metallic manufacturing, processing and smelting industry.W6 are used for applications in metal elemental analysis, trace element analysis for science and industry like Metallurgy, Foundry, Mechanical Engineering, Scientific Research, Product Inspection, Automobile, Petrochemical Engineering, Shipbuilding, Electrics, Aerospace, Nuclear Power, Metallic and Nonferrous Metallic Smelting, Processing and Recycling.
Detection Matrices:
1.Iron(Fe) and its alloys (Steel alloy, Cast iron, Fe-Low alloy, Fe-Cr steel, Fe-Cast iron, Fe-Cr-cast, Fe-Mn steel, Fe-Tool steel etc.)
2.Aluminium(Al) and its alloys (Al-Si alloy, Al-Zn alloy, Al-Cu alloy, Al-Mg alloy, Pure-Al alloy etc)
3.Copper(Cu) and its alloys (Brass, Copper-Nickel-Zn, Aluminum Bronze, Tin-lead Bronze, Red Copper, Be-Bronze, Si-Bronze etc)
4.Nickel(Ni) and its alloys (Pure Ni, Monel metal, Hadtelloy Alloy, Incoloy, Inconel, Nimonic etc)
5.Cobalt(Co) and its alloys (Co-orientation, Low Co alloy, Stellite 6,25,31, Stellite 8,WI 52, Stellite 188, F)
6.Magnesium(Mg) and its alloys (Pure Mg, Mg/Al/Mn/Zn-alloys)
7.Titanium(Ti) and its alloys
8.Zinc(Zn) and its alloys
9.Lead(Pb) and its alloys
10.Tin(Sn) and its alloys
11.Argentum(Ag) and its alloys
12.Small sample, special size sample and wire detection
Parameters
Item |
Index |
Detection of base |
Fe,Al,Cu,Ni,Ti,Co,Zn,Sn,Mg,Pb etc |
Testing time |
According to the sample type, generally about 25s |
Wavelength coverage |
130~800nm |
Focal length |
400mm |
Detector |
The advanced CCD Array |
Electrode |
Tungsten material injection electrode |
Working temperature |
(10~35)℃ |
Working humidity |
20%~85% |
Type of lamp-house |
New digital adjustable light, high energy precombustion technology(HEPS) |
Vacuum system |
The vacuum automatic control and monitoring software |
Working power supply |
220V AC, 50/60Hz |