Thermal Analysis Instruments

Differential scanning calorimeter(DSC)

model: TS-100
Standard:
E-mail: robin@pro-trueview.com


1.TS-100 differential scanning calorimeter (DSC):

Product introduction:
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).

Main Features:
1. New designed oven structure ensures high resolution and good stability of base line;
2. Air flow meter may control the air flow rate accurately; the test data can be recorded into the database directly;
3. The instrument is bilateral control, may be controlled by both main frame and software. User-friendly interface, easy operation.

Technical parameters:
1.   DSC range: 0~±500mW
2.   Temperature range: room temperature ~ 800 ℃ air-cooled
3.   Heating rate: 1 ~ 80℃/min
4.   Temperature resolution: 0.1 ℃
5.   Temperature fluctuations: ±0.1℃
6.   Temperature repeatability: ±0.1℃
7.   DSC noise: 0.01μW
8.   DSC resolution: 0.01μW
9.   DSC accuracy: 0.1μW
10. DSC sensitivity: 0.1μW
11. Control Mode: Rising temperature, constant temperature(full automatic programmed control)
12. Curve scanning: Rising scan, *cooling scan
13. Atmosphere control: Embedded digital flow meter & Software control
14. Color: 24 bit    7 inches LCD touch screen display
15. Data interface: standard USB connector
16. Parameter standard: equipped with standard material, with a key calibration function, the user may correct temperature and heat enthalpy
17. Note: * for selecting projects, all technical indicators can be adjusted according to customers' demand

 

2.TS-100L differential scanning calorimeter (DSC):

Product introduction:
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).

Main Features:
1. New designed oven structure ensures high resolution and good stability of base line;
2. Air flow meter may control the air flow rate accurately; the test data can be recorded into the database directly;
3. The instrument is bilateral control, may be controlled by both main frame and software. User-friendly interface, easy operation.

Technical parameters:
1.   DSC range: 0~±500mW
2.   Temperature range: -100℃ ~ 800 ℃
3.   Heating rate: 1 ~ 80 ℃ / min
4.   Temperature resolution: 0.1 ℃
5.   Temperature fluctuations: ±0.1℃
6.   Temperature repeatability: ±0.1℃
7.   DSC noise: 0.01μW
8.   DSC resolution: 0.01μW
9.   DSC accuracy: 0.1μW
10. DSC sensitivity: 0.1μW
11. Control Mode: Rising temperature, constant temperature(full automatic programmed control)
12. Curve scanning: Rising scan, *cooling scan
13. Atmosphere control: Embedded digital flow meter & Software control
14. Color: 24 bit      7 inches LCD touch screen display
15. Data interface: standard USB connector
16. Parameter standard: equipped with standard material, with a key calibration function, the user may correct temperature and heat enthalpy
17. Note: * for selecting projects, all technical indicators can be adjusted according to customers' demand
Return

Shanghai Trueview Scientific Instrument Co. LTD
Phone: 0086-18007322239 (Robin)
Fax: 0086-734-8770418
Cell: 0086-15367067787
Wechat: 0086-18007322239
Email: robin@pro-trueview.com
Add: Room 118, Block 21, No.1-42, Lane 83 ,Hongxiang North Road, Wanxiang Town, Pudong New Area, Shanghai City, China
Copyright © 2018.Trueview Scientific All rights reserved.